Home / Chemical Engineering / Process Control and Instrumentation :: Section 4

Chemical Engineering :: Process Control and Instrumentation

  1. The inverse Laplace transform of the function is

  2. A.
    1 + et
    B.
    1 - et
    C.
    1 + e-t
    D.
    1 - e-t

    View Answer

    Workspace

    Discuss Discuss in Forum


  3. Thermal conductivity based continuous flue gas analyser makes use of varying thermal conductivity of the constituents of flue gases. Which of the following constituents of flue gases has the maximum thermal conductivity ?

  4. A.
    CO2
    B.
    N2
    C.
    O2
    D.
    CO

    View Answer

    Workspace

    Discuss Discuss in Forum


  5. Emf generated in a thermocouple depends on the temperature

  6. A.
    of cold junction only.
    B.
    of hot junction only.
    C.
    difference between hot and cold junctions.
    D.
    difference between cold junction and atmospheric temperature.

    View Answer

    Workspace

    Discuss Discuss in Forum


  7. Working principle of mercury in glass thermometer is based on the __________ of mercury with increase in temperature.

  8. A.
    increase of pressure
    B.
    increase of thermal conductivity
    C.
    volumetric expansion
    D.
    differential linear expansion

    View Answer

    Workspace

    Discuss Discuss in Forum


  9. The Laplace transform of a sinusoidal function (eg; sin at) is represented by the curve

  10. View Answer

    Workspace

    Discuss Discuss in Forum


  11. Number of poles in a system with transfer function is

  12. A.
    2
    B.
    5
    C.
    3
    D.
    1

    View Answer

    Workspace

    Discuss Discuss in Forum


  13. Radiation thermometer can not measure the temperature

  14. A.
    inside a pressure vessel.
    B.
    of an object without coming in contact with it.
    C.
    of liquid oxygen.
    D.
    of moving objects at high temperature.

    View Answer

    Workspace

    Discuss Discuss in Forum


  15. Temperature measurement by optical pyrometer is done above __________ point, which is 1063°C.

  16. A.
    antimony
    B.
    gold
    C.
    silver
    D.
    nickel

    View Answer

    Workspace

    Discuss Discuss in Forum


  17. Continuous flue gas analyser makes use of paramagnetic properties of some of its constituents, which move towards the strongest part of the magnetic field thus displacing diamagnetic gases. Which of the following gases is diamagnetic ?

  18. A.
    CO2
    B.
    O2
    C.
    NO
    D.
    NO2

    View Answer

    Workspace

    Discuss Discuss in Forum


  19. Dilatometer is used to measure

  20. A.
    stress
    B.
    strain
    C.
    deflection
    D.
    contraction/expansion due to changes in temperature

    View Answer

    Workspace

    Discuss Discuss in Forum