Home / Chemical Engineering / Process Control and Instrumentation :: Section 5

Chemical Engineering :: Process Control and Instrumentation

  1. Thermistors are used in __________ devices.

  2. A.
    voltage measuring
    B.
    temperature measuring
    C.
    temperature compensating
    D.
    both(b)&(c)

    View Answer

    Workspace

    Discuss Discuss in Forum


  3. __________ is the static characteristics of an instrument,

  4. A.
    Response
    B.
    Tine lag
    C.
    Drift
    D.
    dynamic error

    View Answer

    Workspace

    Discuss Discuss in Forum


  5. Phase lag of the frequency response of a second order system to a sinusoidal forcing function

  6. A.
    is 30°
    B.
    is 90° at the most
    C.
    approaches 180° asymptotically
    D.
    is 120°

    View Answer

    Workspace

    Discuss Discuss in Forum


  7. Dead zone in an instrument must be less than __________ percent of the scale.

  8. A.
    0.2
    B.
    1.5
    C.
    4
    D.
    8

    View Answer

    Workspace

    Discuss Discuss in Forum


  9. Emission spectroscopy is used for

  10. A.
    solids and metal analysis.
    B.
    determining water purity.
    C.
    determination of CO2 in gases.
    D.
    NOxdetermination.

    View Answer

    Workspace

    Discuss Discuss in Forum


  11. Gas analysis is commonly done using the

  12. A.
    thermal conductivity cell
    B.
    X-ray diffraction
    C.
    mass spectrometer
    D.
    emission spectrometer

    View Answer

    Workspace

    Discuss Discuss in Forum


  13. The open loop transfer function of a control system is . This represents

  14. A.
    a first order system.
    B.
    dead time system.
    C.
    a first order time lag.
    D.
    a second order system.

    View Answer

    Workspace

    Discuss Discuss in Forum


  15. Thermal conductivity measurement is used for the determination of

  16. A.
    O2 percentage in the flue gas.
    B.
    specific gravity of petrofuels.
    C.
    composition of an alloy.
    D.
    CO2 percentage in the flue gas.

    View Answer

    Workspace

    Discuss Discuss in Forum


  17. Presence of a small amount of water in the organic systems can be determined by the __________ method.

  18. A.
    electrical conductivity
    B.
    polarimetry
    C.
    emission spectroscopy
    D.
    dielectric constant end loss factor

    View Answer

    Workspace

    Discuss Discuss in Forum


  19. The transfer function of a pure dead time system with dead time τd is

  20. A.
    1/(τds + 1)
    B.
    τds + 1
    C.
    ess
    D.
    eτds

    View Answer

    Workspace