  1. In a combined footing for two columns carrying unequal loads, the maximum hogging bending moment occurs at

  2. A.

     Less loaded column

    B.

     More loaded column

    C.

     A point of the maximum shear force

    D.

     A point of zero shear force

    View Answer

    Workspace

    Discuss Discuss in Forum


  3. On piles, the drop must be at least

  4. A.

     80 cm

    B.

     100 cm

    C.

     120 cm

    D.

     140 cm

    View Answer

    Workspace

    Discuss Discuss in Forum


  5. If a bent tendon is required to balance a concentrated load W at the centre of the span L, the central dip h must be at least

  6. A.

     WL/P

    B.

     WL/2P

    C.

     WL/3P

    D.

     WL/4P

    View Answer

    Workspace

    Discuss Discuss in Forum


  7. A singly reinforced concrete beam of 25 cm width and 70 cm effective depth is provided with 18.75 cm² steel. If the modular ratio (m) is 15, the depth of the neutral axis, is

  8. A.

     20 cm

    B.

     25 cm

    C.

     30 cm

    D.

     35 cm

    View Answer

    Workspace

    Discuss Discuss in Forum


  9. As per IS : 456, the reinforcement in a column should not be less than

  10. A.

     0.5% and not more than 5% of cross-sectional area

    B.

     0.6% and not more than 6% of cross-sectional area

    C.

     0.7% and not more than 7% of cross-sectional area

    D.

     0.8% and not more than 8% of cross-sectional area

    View Answer

    Workspace

    Discuss Discuss in Forum


  11. If the diameter of longitudinal bars of a square column is 16 mm, the diameter of lateral ties should not be less than

  12. A.

     4 mm

    B.

     5 mm

    C.

     6 mm

    D.

     8 mm

    View Answer

    Workspace

    Discuss Discuss in Forum


  13. The diameter of main bars in R.C.C. columns, shall not be less than

  14. A.

     6 mm

    B.

     8 mm

    C.

     10 mm

    D.

     12 mm

    View Answer

    Workspace

    Discuss Discuss in Forum


  15. Minimum spacing between horizontal parallel reinforcement of the same size should not be less than

  16. A.

     One diameter

    B.

     2.5 diameters

    C.

     3 diameters

    D.

     3.5 diameters

    View Answer

    Workspace

    Discuss Discuss in Forum


  17. Minimum spacing between horizontal parallel reinforcement of different sizes, should not be less than

  18. A.

     One diameter of thinner bar

    B.

     One diameter of thicker bar

    C.

     Twice the diameter of thinner bar

    D.

     None of these

    View Answer

    Workspace

    Discuss Discuss in Forum


  19. If W is total load per unit area on a panel, D is the diameter of the column head, L is the span in two directions, then the sum of the maximum positive bending moment and average of the negative bending moment for the design of the span of a square flat slab, should not be less than

  20. A.

     WL/12 (L - 2D/3)²

    B.

     WL/10 (L + 2D/3)²

    C.

     WL/10 (L - 2D/3)²

    D.

     WL/12 (L - D/3)²

    View Answer

    Workspace