Home / ECE / Measurements and Instrumentation :: Section 8

ECE :: Measurements and Instrumentation

  1. Two resistances are R1 = 36 ± 5% and R2 = 75 ± 5%. If they are connected in parallel, the limiting error in percent will be

  2. A.
    5%
    B.
    10%
    C.
    15%
    D.
    20%

    View Answer

    Workspace

    Discuss Discuss in Forum


  3. For critical damping, the resistance in D'Arsonval galvanometer circuit should be equal to

  4. View Answer

    Workspace

    Discuss Discuss in Forum


  5. An ac bridge uses galvanometer as detector.

  6. A.
    True
    B.
    False

    View Answer

    Workspace

    Discuss Discuss in Forum


  7. In figure, the reading of wattmeter will be proportional

  8. A.
    V I cos θ
    B.
    3 VI cos θ
    C.
    3 VI sin θ
    D.
    V I sin θ

    View Answer

    Workspace

    Discuss Discuss in Forum


  9. Consider the following statements about mutual inductances:

    1. The value should remain constant under all conditions.
    2. The mutual inductance should not vary with temperature.
    3. The inductance should be independent of excitation.
    4. They have two coils wound on a bobbin of hard magnetic material, coils being separated by a range.
    Out of the above, correct statement are

  10. A.
    2, 3, 4
    B.
    1, 2, 3
    C.
    1, 3, 4
    D.
    1, 2, 4

    View Answer

    Workspace

    Discuss Discuss in Forum


  11. In low power factor wattmeter, the pressure coil is connected

  12. A.
    to the supply side of current coil
    B.
    to the load side of current coil
    C.
    in either (a) or (b)
    D.
    across the mains

    View Answer

    Workspace

    Discuss Discuss in Forum


  13. Figure shows the equivalent circuit of resistor. The resistor is non-inductive when

  14. A.
    R = L/C
    B.
    LR = L/C
    C.
    L = CR2
    D.
    C = LR2

    View Answer

    Workspace

    Discuss Discuss in Forum


  15. The signal to noise ratio in telemetry should be better than

  16. A.
    5 db
    B.
    10 db
    C.
    25 db
    D.
    60 db

    View Answer

    Workspace

    Discuss Discuss in Forum


  17. Assertion (A): Electrodynamic instrument is not used as ammeter or voltmeter.

    Reason (R): Electrodynamic instrument is more costly than PMMC and moving iron instrument.

  18. A.
    Both A and R are true and R is correct explanation of A
    B.
    Both A and R are true but R is not correct explanation of A
    C.
    A is true R is false
    D.
    A is false R is true

    View Answer

    Workspace

    Discuss Discuss in Forum


  19. Consider the following statements regarding electro-dynamometer type indicating instrument
    It can be used for measuring

    1. Direct current
    2. Alternating current
    3. Direct voltage
    4. Alternating voltage
    Of these statements

  20. A.
    1 and 2 are corect
    B.
    3 and 4 are correct
    C.
    1 and 3 are correct
    D.
    1, 2, 3, 4 are correct

    View Answer