Home / ECE / Measurements and Instrumentation :: Section 10

ECE :: Measurements and Instrumentation

  1. A direct current can be measured

  2. A.
    directly by dc potentiometer
    B.
    by dc potentiometer in conjunction with a standard resistance
    C.
    by dc potentiometer in conjunction with volt ratio box
    D.
    none of the above

    View Answer

    Workspace

    Discuss Discuss in Forum


  3. Consider the following galvanometers

    1. D'Arsonval
    2. Ballistic
    3. Vibration
    Which of these are permanent magnet moving coil instruments?

  4. A.
    1 and 2 only
    B.
    1, 2 and 3
    C.
    2 and 3 only
    D.
    1 and 3 only

    View Answer

    Workspace

    Discuss Discuss in Forum


  5. Assertion (A): Hall effect is observed in all metals but is very appreciable in semiconductors.

    Reason (R): Hall effect transducer is very suitable for measurement of magnetic flux density.

  6. A.
    Both A and R are true and R is correct explanation of A
    B.
    Both A and R are true but R is not correct explanation of A
    C.
    A is true R is false
    D.
    A is false R is true

    View Answer

    Workspace

    Discuss Discuss in Forum


  7. Assertion (A): The trigger circuit of a CRO is excited by the same signal as Y plates.

    Reason (R): The time base generator develops a saw tooth voltage.

  8. A.
    Both A and R are true and R is correct explanation of A
    B.
    Both A and R are true but R is not correct explanation of A
    C.
    A is true R is false
    D.
    A is false R is true

    View Answer

    Workspace

    Discuss Discuss in Forum


  9. A data signal having frequency components from dc to 50 Hz is to be sent through pulse code modulation using an 8 digit code. The minimum carrier channel bandwidth is

  10. A.
    1 kHz
    B.
    2 kHz
    C.
    4 kHz
    D.
    8 kHz

    View Answer

    Workspace

    Discuss Discuss in Forum


  11. If Eb is the potential of accelerating anode, the energy of electrons as they emerge from electron gun is proportional to

  12. A.
    Eb
    B.
    Eb
    C.
    Eb1.5
    D.
    Eb2

    View Answer

    Workspace

    Discuss Discuss in Forum


  13. A moving iron instrument has

  14. A.
    two iron vanes, one fixed and one movable
    B.
    two movable iron vanes
    C.
    two aluminium vanes, one fixed and one movable
    D.
    two vanes, one fixed made of Aluminium and the other movable made of iron

    View Answer

    Workspace

    Discuss Discuss in Forum


  15. The temperature coefficient of resistance for a thermistor is

  16. A.
    low and negative
    B.
    low and positive
    C.
    high and negative
    D.
    high and positive

    View Answer

    Workspace

    Discuss Discuss in Forum


  17. To measure an unknown ac voltage by an ac potentiometer it is desirable that supply for the potentiometer is taken

  18. A.
    from a battery
    B.
    from a source which is not the same as unknown voltage
    C.
    from the same source as the unknown voltage
    D.
    either (a) or (b)

    View Answer

    Workspace

    Discuss Discuss in Forum


  19. A linear displacement digital transducer generally uses

  20. A.
    straight binary code
    B.
    BCD
    C.
    gray code
    D.
    hexadecimal code

    View Answer

    Workspace