Home / ECE / Power Electronics :: Section 1

ECE :: Power Electronics

  1. A cycloconverter can be

  2. A.
    step down
    B.
    step up
    C.
    step down or step up
    D.
    none of the above

    View Answer

    Workspace

    Discuss Discuss in Forum


  3. In the below figure the average load current is 15 A. The rms value of transformer secondary current is

  4. A.
    15 A
    B.
    10.61 A
    C.
    7.5 A
    D.
    14.14 A

    View Answer

    Workspace

    Discuss Discuss in Forum


  5. In a 3 phase fully controlled converter the firing frequency is

  6. A.
    3 times the line frequency
    B.
    6 times the line frequency
    C.
    9 times the line frequency
    D.
    12 times the line frequency

    View Answer

    Workspace

    Discuss Discuss in Forum


  7. Two thyristor of same rating and same specifications

  8. A.
    will have equal turn on and turn off periods
    B.
    will have equal turn on but unequal turn off periods
    C.
    may have equal or unequal turn on and turn off periods
    D.
    will have unequal turn on and turn off periods

    View Answer

    Workspace

    Discuss Discuss in Forum


  9. The amount of dielectric heating is inversely proportional to frequency.

  10. A.
    True
    B.
    False

    View Answer

    Workspace

    Discuss Discuss in Forum


  11. A semiconverter feeding an RLE load operates in

  12. A.
    first quadrant only
    B.
    first and second quadrants
    C.
    first and fourth quadrants
    D.
    first and third quadrants

    View Answer

    Workspace

    Discuss Discuss in Forum


  13. The phenomenon of overlap in converter operation due to

  14. A.
    source resistance
    B.
    source inductance
    C.
    both source resistance and source inductance
    D.
    high value of firing angle

    View Answer

    Workspace

    Discuss Discuss in Forum


  15. A thyristor has a maximum allowable junction temperature of 120°C and the ambient temperature is 40°C. If thermal resistance is 1.6° C/W, the maximum allowable internal power dissipation is

  16. A.
    20 W
    B.
    50 W
    C.
    92 W
    D.
    128 W

    View Answer

    Workspace

    Discuss Discuss in Forum


  17. For a 12 pulse operation, the two 6 pulse units are fed by

  18. A.
    Y - Y and Y - Y transformers
    B.
    Δ - Δ and Δ - Δ transformers
    C.
    Y - Y and Y - Δ transformers
    D.
    Y - Δ and Y - Δ transformers

    View Answer

    Workspace

    Discuss Discuss in Forum


  19. In a single phase full wave converter (M - 2 connection) feeding a highly inductive load, the firing angle for each thyristor is a in the respective half cycle. The period of conduction of each thyristor is

  20. A.
    p - a
    B.
    p
    C.
    p + a
    D.
    p - 2a

    View Answer

    Workspace

    Discuss Discuss in Forum