Home / EEE / D.C. Generators :: section-1

EEE :: D.C. Generators

  1. In a level compounded D.C. generator, full load terminal voltage is

  2. A.

     Negligibly low

    B.

     Equal to no-load terminal voltage

    C.

     More than no-load terminal voltage

    D.

     Less than no-load terminal voltage

    View Answer

    Workspace

    Discuss Discuss in Forum


  3. In D.C. generators the pole shoes are fastened to the pole core by

  4. A.

     Rivets

    B.

     Counter sunk screws

    C.

     Brazing

    D.

     Welding

    View Answer

    Workspace

    Discuss Discuss in Forum


  5. Which generator would you prefer for feeding long D.C. transmission lines?

  6. A.

     Series generator

    B.

     Shunt generator

    C.

     Over compound generator

    D.

     Flat compound generator

    View Answer

    Workspace

    Discuss Discuss in Forum


  7. In D.C. generators, lap winding is used for

  8. A.

     High voltage, high current

    B.

     Low voltage, high current

    C.

     High voltage, low current

    D.

     Low voltage, low current

    View Answer

    Workspace

    Discuss Discuss in Forum


  9. Copper brushes in D.C. machine are used

  10. A.

     Where low voltage and high currents are involved

    B.

     Where high voltage and small currents are involved

    C.

     In both of the above cases

    D.

     In none of the above cases

    View Answer

    Workspace

    Discuss Discuss in Forum


  11. A shunt generator running at 1000 r.p.m. has generated e.m.f. as 200 V. If the speed increases to 1200 r.p.m., the generated e.m.f. will be nearly

  12. A.

     150 V

    B.

     175 V

    C.

     240 V

    D.

     290 V

    View Answer

    Workspace

    Discuss Discuss in Forum


  13. For both lap and wave windings, there are as many commutator bars as the number of

  14. A.

     Slots

    B.

     Armature conductors

    C.

     Winding elements

    D.

     Poles

    View Answer

    Workspace

    Discuss Discuss in Forum


  15. Armature reaction of an unsaturated D.C. machine is

  16. A.

     Cross-magnetizing

    B.

     Demagnetizing

    C.

     Magnetizing

    D.

     None of above

    View Answer

    Workspace

    Discuss Discuss in Forum


  17. Two generators A and B have 6 poles each. Generator A has wave wound armature while generator B has lap wound armature. The ratio of the induced e.m.f. is generator A and B will be

  18. A.

     2 : 3

    B.

     3 : 1

    C.

     3 : 2

    D.

     1 : 3

    View Answer

    Workspace

    Discuss Discuss in Forum


  19. A shunt generator can self-excite

  20. A.

     Only if the resistance of the field circuit is less than critical value

    B.

     Only if the resistance of the field circuit is greater than critical value

    C.

     Irrespective of the value of the resistance in the field circuit

    D.

     None of the above

    View Answer

    Workspace