  1. The angle δ for a mica capacitor is about

  2. A.
    25°
    B.
    15°
    C.
    D.

    View Answer

    Workspace

    Discuss Discuss in Forum


  3. A digital voltmeter has a read out range from 0 to 999 counts. If the full scale reading is 9.999 V, the resolution is

  4. A.
    1 V
    B.
    0.01 V
    C.
    1 mV
    D.
    1 μV

    View Answer

    Workspace

    Discuss Discuss in Forum


  5. The coil of a moving coil meter has 100 turns, is 40 mm long and 30 mm wide. The control torque is 240 x 10-6 N-m on full scale. If B = 1 Wb/m2, range of meter is

  6. A.
    1 mA
    B.
    2 mA
    C.
    3 mA
    D.
    4 mA

    View Answer

    Workspace

    Discuss Discuss in Forum


  7. Consider the following statements: In a differential amplifier using JFET, the differential output offset is due to

    1. mismatch between FET parameters
    2. difference in values of resistances used in circuit
    3. variation in supply voltage.
    Of the statements, the correct statements are

  8. A.
    1 and 2
    B.
    1, 2, 3
    C.
    2, 3
    D.
    1, 3

    View Answer

    Workspace

    Discuss Discuss in Forum


  9. Magnetic flux density has the dimensions

  10. A.
    MI-1T-2
    B.
    M-1I-2T-2
    C.
    ML-3T-2
    D.
    MI-1T-3

    View Answer

    Workspace

    Discuss Discuss in Forum


  11. A meter with a resistance of 100 Ω and a full scale deflection of current of 1 mA is to be converted into voltmeter of 0 - 5 V range. The multiplier resistance should be

  12. A.
    490 Ω
    B.
    5000 Ω
    C.
    4900 Ω
    D.
    5100 Ω

    View Answer

    Workspace

    Discuss Discuss in Forum


  13. In a resistance strain gauge, G = 2, stress = 1050 kg/cm2, R = 1000 Ω. The value of ΔR will be

  14. A.
    2 Ω
    B.
    3 Ω
    C.
    4 Ω
    D.
    1 Ω

    View Answer

    Workspace

    Discuss Discuss in Forum


  15. The household energy meter is

  16. A.
    indicating instrument
    B.
    recording instrument
    C.
    integrating instrument
    D.
    none of the above

    View Answer

    Workspace

    Discuss Discuss in Forum


  17. A standard cell of 1.0185 V is used with a slide wire potentiometer. The balance was obtained at 60 cm. When an unknown emf was connected, the balance was obtained at 82 cm. The magnitude of unknown emf is

  18. A.
    1.39 V
    B.
    0.75 V
    C.
    13.9 V
    D.
    7.45 V

    View Answer

    Workspace

    Discuss Discuss in Forum


  19. A full wave rectifier type meter is used to measure the wave shape shown in figure. The voltmeter is calibrated to read rms value of sine wave. The reading of voltmeter will be

  20. A.
    B.
    C.
    100 V
    D.
    111 V

    View Answer

    Workspace

    Discuss Discuss in Forum