Home / EEE / Electric Transmission and Distribution :: Electric transmission and distribution

EEE :: Electric Transmission and Distribution

  1. The inductance of a single phase two wire line is given by (D is the distance between conductors and 2v is the diameter of conductor)
  2. A.
    0.4 loge (D/r) mH/km
    B.
    0.55 loge (D/r) mH/km
    C.
    0.4 loge (r/D) mH/km
    D.
    0.55 loge (r/D) mH/km

    View Answer

    Workspace

    Discuss Discuss in Forum


  3. Between two supports, due to sag the conductor takes the form of
  4. A.
    catenary
    B.
    triangle
    C.
    ellipse
    D.
    semi-circle

    View Answer

    Workspace

    Discuss Discuss in Forum


  5. Presence of ozone as a result of corona is harmful because
  6. A.
    it gives bad odor
    B.
    it corrodes the material
    C.
    it transfers energy to the ground
    D.
    reduces power factor

    View Answer

    Workspace

    Discuss Discuss in Forum


  7. The current drawn by the line due to corona losses is
  8. A.
    sinusoidal
    B.
    square
    C.
    non-sinusoidal

    View Answer

    Workspace

    Discuss Discuss in Forum


  9. Corona effect can be detected by
  10. A.
    hissing sound
    B.
    faint luminous flow of bluish color
    C.
    presence of ozone detected by odor
    D.
    all of the above

    View Answer

    Workspace

    Discuss Discuss in Forum


  11. Corona usually occurs when the electrostatic stress in the air around the conductor succeeds
  12. A.
    30 kV (maximum value)/cm
    B.
    22 kV (maximum value)/cm
    C.
    11 kV (rms value)/cm
    D.
    6.6 kv (rms value)/cm

    View Answer

    Workspace

    Discuss Discuss in Forum


  13. The effect of corona is
  14. A.
    increased energy loss
    B.
    increased reactance
    C.
    increased inductance
    D.
    all of the above

    View Answer

    Workspace

    Discuss Discuss in Forum


  15. Ten discs usually suggest that the transmission line voltage is
  16. A.
    11 kV
    B.
    33 kV
    C.
    66 kV
    D.
    132 kV

    View Answer

    Workspace

    Discuss Discuss in Forum


  17. For 66 kV lines the number of insulator discs used are
  18. A.
    3
    B.
    5
    C.
    8
    D.
    12

    View Answer

    Workspace

    Discuss Discuss in Forum


  19. Strain type insulator arc used where the conductors arc
  20. A.
    dead ended
    B.
    at intermediate anchor towers
    C.
    any of the above
    D.
    none of the above

    View Answer

    Workspace