Home / Civil Engineering / Structural Design Specifications :: Section 1

Civil Engineering :: Structural Design Specifications

  1. The area of the concrete in compression plus the area of reinforcement transferred on the basis of modular ratio, is called

  2. A.
    transferred section
    B.
    equivalent section
    C.
    cracked section
    D.
    none of these.

    View Answer

    Workspace

    Discuss Discuss in Forum


  3. If D is the overall thickness of the slab, the diameter of the reinforcing bars should not exceed

  4. View Answer

    Workspace

    Discuss Discuss in Forum


  5. The gap between web plates and flange plates for fillet welds should not be more than

  6. A.
    0.5 mm
    B.
    0.75 mm
    C.
    1.0 mm
    D.
    1.25 mm
    E.
    1.5 mm

    View Answer

    Workspace

    Discuss Discuss in Forum


  7. A continuous beam shall be deemed to be a deep beam if the ratio of its effective span to overall depth, is

  8. A.
    2.0
    B.
    2.5
    C.
    less than 2
    D.
    less than 2.5

    View Answer

    Workspace

    Discuss Discuss in Forum


  9. The depth 'd' of webs without horizontal stiffeners and consisting of tongue plates is taken lesser than the depth of the girder between the flanges less the sum of the depth of the tongue plates, and

  10. A.
    eight times the sum of the thickness of tongue plates
    B.
    six times the sum of the thickness of tongue plates
    C.
    four times the sum of the thickness of tongue plates
    D.
    None of the above.

    View Answer

    Workspace

    Discuss Discuss in Forum


  11. For design of a column the eccentricity of loading shall be taken as the distance from the assumed point of application of the load to the centroid of the column, subject to a minimum of

  12. A.
    10 mm
    B.
    20 mm
    C.
    30 mm
    D.
    40 mm
    E.
    50 mm

    View Answer

    Workspace

    Discuss Discuss in Forum


  13. If l is the effective span in metres and D is overall depth of the section in mm, the structure may be accepted after 24 hour load test, provided the maximum deflection in mm is less than

  14. View Answer

    Workspace

    Discuss Discuss in Forum


  15. The approximate value of torsion constant k for a box of depth d, width b, and having uniform thickness t, is

  16. View Answer

    Workspace

    Discuss Discuss in Forum


  17. In the formula a + bk for the calculation of the net effective section of single angles in tension connected by one leg only, the value of k, is

  18. View Answer

    Workspace

    Discuss Discuss in Forum


  19. The concrete is deemed not to comply with the strength requirements if the strength is less than the greater of

  20. A.

    characteristic strength minus 1.35 times the standard deviation

    B.

    0.8 times the characteristic strength

    C.

    the average strength of all the samples is less than the characteristic strength plus times the standard deviation.

    D.

    all the above.