Home / ECE / Digital Electronics :: Section 17

ECE :: Digital Electronics

  1. Consider the following statements

    1. ECL has least propagation delay
    2. TTL has largest fan out
    3. CMOS has highest noise margin
    4. TTL has lowest power dissipation
    Which of these are correct?

  2. A.
    1 and 3
    B.
    2 and 4
    C.
    3 and 4
    D.
    1 and 2

    View Answer

    Workspace

    Discuss Discuss in Forum


  3. In Schottky TTL, a Schottky diode is used for

  4. A.
    forming the gate
    B.
    connecting the resistor
    C.
    clamping of the basic collector junction
    D.
    none of the above

    View Answer

    Workspace

    Discuss Discuss in Forum


  5. The circuit of the given figure is

  6. A.
    full adder
    B.
    magnitude comparator
    C.
    parity detector
    D.
    none of the above

    View Answer

    Workspace

    Discuss Discuss in Forum


  7. Which of the following ICs has only one NAND gate?

  8. A.
    7410
    B.
    7420
    C.
    7430
    D.
    7447

    View Answer

    Workspace

    Discuss Discuss in Forum


  9. A mod-10 counter can divide the clock frequency by a factor of

  10. A.
    10
    B.
    20
    C.
    210
    D.
    102

    View Answer

    Workspace

    Discuss Discuss in Forum


  11. In a digital circuit, a clock is a

  12. A.
    crystal type
    B.
    multivibrator
    C.
    flip-flop
    D.
    free running multivibrator

    View Answer

    Workspace

    Discuss Discuss in Forum


  13. In a RS flip-flop no change occurs during

  14. A.
    prohibited mode
    B.
    set mode
    C.
    reset mode
    D.
    disable mode

    View Answer

    Workspace

    Discuss Discuss in Forum


  15. Out of multiplexer and demultiplexer, which can be used as a logic function generator?

  16. A.
    Multiplexer only
    B.
    Demultiplexer only
    C.
    Both
    D.
    None

    View Answer

    Workspace

    Discuss Discuss in Forum


  17. Binary 1000 will be the result of which of the following?

  18. A.
    Binary 1000 - 100
    B.
    Binary 1011 - 1111
    C.
    Binary 1111 - 111
    D.
    Binary 11111 - 1111

    View Answer

    Workspace

    Discuss Discuss in Forum


  19. In a programmable counter

  20. A.
    the starting number for counting can be programmed
    B.
    the modulus can be programmed
    C.
    both the starting number and modulus can be programmed
    D.
    either the starting number or modulus can be programmed

    View Answer

    Workspace

    Discuss Discuss in Forum